E-Catalog > miniBOOSTER > miniBOOSTER Product

PAGE VIEW : 12,162

Product Information :

Name :
miniBOOSTER Product
Category :
  1. เครื่องจักร, อุปกรณ์เกี่ยวกับเครื่องจักร, เครื่องมือกล
Sub - Category :
  1. miniBOOSTER
Brand :
miniBOOSTER
Model :
HC1/HC2/HC3/HC4/HC6/HC7/HC8/HC9/HC2W/HC4W/HC7W/HC8W/HC2D/HC6D/HC2Dc/HC6D2
Product Type :
  1. สินค้า, ผลิตภัณฑ์
Short Description :
HC1/HC2/HC3/HC4/HC6/HC7/HC8/HC9/HC2W/HC4W/HC7W/HC8W/HC2D/HC6D/HC2Dc/HC6D2

Product Detail :

Product Range

The complete product range of hydraulic intensifiers from miniBOOSTER

For further product details, please select the specific model link.

For download of 3D cad files for each product, please visit our Download Section.

Outlet
pressure
(bar)

Average
outlet flow
(l/min)

Inlet
pressure
(bar)

Inlet
flow
(l/min)

Connection

Weight
(kg)

Ratio

Model:
Steel

Model:
Stainless
steel

24–800

0.3–0.5

20–200

2.0–8.0

Tube

0.7

1.2–7.5

HC1

24–800

0.3–2.5

20–200

2.0–15.0

Tube

1.0

1.2–20.0

HC2

HC2W

24–800

0.7–11.0

20–200

2.0–15.0

Tube

3.8

1.2–20.0

HC2D

 

20–800

2.0–3.0

20–200

2.0–15.0

Tube

4.15

1.0–10.1

HC2D2

 

24–800

0.3–1.0

Tube

2.1

1.2-13.0

HC2P

 

24–500

0.3–2.5

20–200

2.0–15.0

Manifold NG6/DO3

2.5

1.2–20.0

HC3

 

24–500

0.3–2.5

20–200

2.0–15.0

Manifold NG6/DO3

4.0

1.2–20.0

HC3 - C

 

24–500

0.3–2.5

20–200

2.0–15.0

Manifold

1.75

1.2–20.0

HC3 - D

 

24–500

0.3–2.5

20–200

2.0–15.0

Manifold

4.3

1.2–20.0

HC3 - F

 

24–500

0.3–2.5

20–200

2.0–15.0

Manifold NG6/DO3

3.3

1.2–20.0

HC3 - H

 

24–500

0.3–2.5

20–200

2.0–15.0

Manifold NG6/DO3

3.5

1.2–20.0

HC3 - I

 

26–800

1.5–7.0

20–200

2.0–35.0

Tube

3.7

1.3–9.8

HC4

HC4W

24–800

0.3–2.5

20–200

2.0–15.0

Tube

3.0

1.2–20.0

HC5

 

26–800

2.5–15.0

20–200

5.0–70.0

Tube

9.5

1.3–8.2

HC6

 

24–800

11.2–56.0

20–200

5.0–70.0

Tube

20.0

1.2–8.2

HC6D

 

20–800

6.0–41.0

20–200

5.0–70.0

Tube

22.0

1.0–10.1

HC6D2

HC6D2W

100–2000

0.3–1.6

20–200

2.0–14.0

Tube

1.5

5.0–20.0

HC7

HC7W

100–2000

0.3–1.6

20–200

2.0–14.0

Tube

5.0

5.0–20.0

HC8

 

220–5000

0.3–1.8

20–200

5.0–20.0

Tube

9.9

8.2–25.0

HC9

 

Other products from miniBOOSTER

For further product details, please select the specific product link.

Filters

Valve Houses

Accessories

In-Line Filter

CV1

Adapter Kits

High Pressure T-filter

CV2

Adapters

T-filter

CV3

Pilot Operated Check Valve

Filter Housing

CV4

 

NG6 Filter

CV5

 

Power Packs

Intensifier Systems

 

Hydraulic Power Pack

Intensifier System M-HC6 500 bar

 

Hydraulic Power Pack Tower

Portable Intensifier System M-HC7 2000 bar

 
 

Portable Intensifier System M-HC7 800 bar

 

The HC1 miniBOOSTER

HC1 versions: 9 different intensification factors

PIN: 20 – 200 bar (inlet pressure)

PH: 800 bar maximum (outlet pressure)

PRETURN: As low as possible (Return pressure to tank)

Intensification ratios: PH = (PIN – PReturn) i (Intensification)

Mounting: Inline tube

Accessories: Pilot operated dump valve available

A model = no dump valve
B model = with dump valve
G model = direct proportionally controlled

 

Description

The HC1 is the most compact miniBOOSTER unit weighing only 0.7 kg. It is ideal for use in applications where it is desirable to mount the unit on or in a tool, power pack, or other device. 

The HC1 raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure.

 Intensification factor
 i 

 Max. outlet flow
 l/min 

 Max. inlet flow
 l/min 

 1.2 

 0.5 

 8.0 

 1.5 

 0.5 

 8.0 

 2.0 

 0.5 

 8.0 

 2.8 

 0.5 

 8.0 

 3.3 

 0.5 

 8.0 

 4.0 

 0.4 

 8.0 

 4.8 

 0.4 

 8.0 

 6.2 

 0.3 

 8.0 

 7.5 

 0.3 

8.0

Dimensions

Functions

The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the check valves KV1, KV2 and DV to the high pressure side H. In this condition maximum flow through the booster is achieved giving a fast forward function.

When pump pressure is reached on the high pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when end pressure on high pressure side H is reached. If there is a pressure drop on the high pressure side due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.


Function Diagram

Connection types

Connection

IN / R

H

1

1/8" BSP

1/4" BSP

2

3/8-24 UNF

9/16-18 UNF

Max. tightening torque BSP

 

IN / R

H

 

1/8" BSP

1/4" BSP

with steel washer

2.0 da/Nm

4.0 da/Nm

with aluminium washer

1.0 da/Nm

with cutting edge

2.0 da/Nm

4.0 da/Nm

Max. tightening torque UNF

 

IN / R

H

 

3/8-24" UNF

  9/16-18" UNF

  with o-ring

1.5 da/Nm

3.5 da/Nm

Fluids and materials

Please see General Specifications.

 

Ordering a HC1

Ordering example of a HC1 with i = 3.3, DV incorporated and BSP connections: HC1 - 3.3 - B - 1

Model

 

Intensification, i

 

Dump Valve

 

Connections

HC1


 your selection...


 your selection...


 your selection...

             
 

see flow rate table

 

A = (no) / A model

 

1

 

B = (yes) / B model

2

G = (proportional) / G model

 
 



The HC4 miniBOOSTER

HC4 versions: 9 different intensification factors

PIN: 20 – 200 bar (inlet pressure)

PH: 800 bar maximum (outlet pressure)

PRETURN: As low as possible (Return pressure to tank)

Intensification ratios: PH = (PIN – PReturn) i (Intensification)

Mounting: Inline tube

Accessories: Pilot operated dump valve available

A model = no dump valve
B model = with dump valve
G model = direct proportionally controlled

 

Description

The HC4 is ideal for use in applications where a higher volume of high pressure fluid is required. The HC4 is a compact unit weighing only 3.7 kg, but it delivers up to 5.0 liters/min. outlet flow. Like the HC2, it raises supplied pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure.

Flow Rates

Intensification factor
i

Max. outlet flow
l/min

Max. inlet flow
l/min

1.3

1.5

25.0

1.8

1.2

25.0

2.1

7.0

35.0

2.8

6.0

35.0

3.2

5.0

35.0

4.3

4.0

35.0

5.1

3.5

35.0

6.3

2.5

35.0

9.8

2.0

35.0

Dimensions

Functions

The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the check valves KV1, KV2 and DV to the high pressure side H. In this condition maximum flow through the booster is achieved giving a fast forward function.

When pump pressure is reached on the high pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when end pressure on high pressure side H is reached. If there is a pressure drop on the high pressure side due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.

Function Diagram

Connection types

Connection

IN / R

H

1

3/8" BSP

1/2" BSP

2

9/16-18 UNF

3/4-16 UNF

Max. tightening torque BSP

 

IN / R

H

 

3/8" BSP

1/2" BSP

  with steel washer

6.0 da/Nm

13.0 da/Nm

  with aluminium washer

4.0 da/Nm

  with cutting edge

6.0 da/Nm

13.0 da/Nm

 

Max. tightening torque UNF

 

IN / R

H

 

9/16-18" UNF

  3/4-16" UNF

  with o-ring

3.5 da/Nm

6.0 da/Nm

 

Fluids and materials

Please see General Specifications

Ordering a HC4

Ordering example of a HC4 with i = 4.3, DV incorporated and BSP connections: HC4 - 4.3 - B - 1

Model

 

Intensification, i

 

Dump Valve

 

Connections

HC4


 your selection...


 your selection...


 your selection...

             
 

see flow rate table

 

A = (no) / A model

 

1

 

B = (yes) / B model

2

G = (proportional) / G model

 

The HC3-I miniBOOSTER

HC3 - I versions: 11 different intensification factors

PIN: 20 – 200 bar (inlet pressure)

PH: 500 bar maximum (outlet pressure)

PRETURN: As low as possible (Return pressure to tank)

Intensification ratios: PH = (PIN – PReturn) i (Intensification)

Mounting: NG6 (D03) stacking manifold system

Accessories: Pilot operated dump valve available

A model = no dump valve
B model = with dump valve
G model = direct proportionally controlled

 

Description

The HC3 - I is a variant of the HC3 providing high-pressure on the B port. It is designed for use in NG6 (D03) stacking manifold systems. The unit is compact weighing only 3.5 kg.

The HC3 has the pilot operated dump valve incorporated as a standard feature. Maximum outlet pressure is 500 bar in standard versions. Adjustments of the outlet pressure is carried out by varying the supplied pressure.

Flow Rates

Intensification factor
i

Max. outlet flow
l/min

Max. inlet flow
l/min

1.2

1.2

8.0

1.5

1.0

8.0

2.0

2.0

12.0

2.8

2.2

13.0

3.2

2.5

15.0

4.0

2.0

14.0

5.0

1.6

14.0

6.6

1.3

13.0

9.0

0.9

13.0

13.0

0.6

12.0

20.0

0.3

12.0

 

Dimensions

Functions

The basic operation is illustrated in the function diagram. The oil is fed through the connecting plate to the control valve to the IN port of the HC3 flowing freely through check valves KV1, KV2 and DV to the high-pressure side H.

From the high-pressure side H oil is fed to port B on the connecting plate. In this condition maximum flow through the booster is achieved giving a fast forward function. When pump pressure is reached on the high-pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when end pressure on high-pressure side is reached. If there is a pressure drop on the high- pressure side due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.


Function Diagram

Fluids and materials

Please see General Specifications

Ordering a HC3-I

Ordering example of a HC3 - I with i = 4.0, DV incorporated: HC3 - 4.0 - B - I

Model

 

Intensification, i

 

Dump Valve

 

Model

HC3


 your selection...


 your selection...


I

             
 

see flow rate table

 

A = (no) / A model

   
 

B = (yes) / B model

 

G = (proportional) / G model

 

The HC2W miniBOOSTER

HC2W versions: 11 different intensification factors

PIN: Inlet pressure 20-200 bar

PH: 800 bar maximum (outlet pressure)

PRETURN: As low as possible (Return pressure to tank)

Intensification ratios: PH = (PIN – PReturn) i (Intensification)

Mounting: Inline tube

Accessories: Pilot operated dump valve available

A model = no dump valve
B model = with dump valve
G model = direct proportionally controlled

 

 

Description

The HC2W is a compact stainless steel unit weighing only 1.0 kg. It is ideal for use in a variety of applications where building and maintaining high pressure is required.

The HC2W raises supplied pressure to a higher outlet pressure and automatically compensates for consumption to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure.

Flow Rates

Intensification factor
i

Max. outlet flow
l/min

Max. inlet flow
l/min

1.2

1.2

8.0

1.5

1.0

8.0

2.0

0.8

8.0

2.8

0.6

8.0

3.2

2.5

15.0

4.0

2.0

14.0

5.0

1.6

14.0

6.6

1.3

13.0

9.0

0.9

13.0

13.0

0.6

12.0

20.0

0.3

12.0

Dimensions

2-120 / Issue 02

Functions

The basic operation is illustrated in the function diagram. Media is fed through the directional valve CV to the IN port, flowing freely through the check valves KV1, KV2 and DV to the high pressure side H. In this condition maximum flow through the booster is achieved giving a fast forward function.

When pump pressure is reached on the high pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when end pressure on high pressure side H is reached. If there is a pressure drop on the high pressure side due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.

Function Diagram

2-105 / Issue 01

Connection types

Connection

IN / R

H

1

1/4" BSP

1/4" BSP

Max. tightening torque BSP

 

IN / R

H

 

1/4" BSP

1/4" BSP

  with stanley steel washer

4.0 da/Nm

4.0 da/Nm

Fluids and materials

Please see General Specifications

Ordering a HC2W

Ordering example of a HC2W with i = 4.0,  DV incorporated and BSP connections:
 HC2W - 4.0 - B - 1 For media < 5 cSt (mm2/s) tested in water
 HC2W - 4.0 - B - 1S For media > 5 cSt (mm2/s) tested in hydraulic oil

 

Model

 

Intensification, i

 

Dump Valve

 

Connections

HC2W


your selection...


your selection...


your selection...

 

see flow rate table

 

A = (no) /A model

 

1

 

B = (yes) /B model

 

G = (proportional)/G model


The HC6 miniBOOSTER

HC6 versions: 9 different intensification factors

PIN: 20 – 200 bar (inlet pressure)

PH: 800 bar maximum (outlet pressure)

PRETURN: As low as possible (Return pressure to tank)

Intensification ratios: PH = (PIN – PReturn) i (Intensification)

Mounting: Inline tube

Accessories: Pilot operated dump valve available

A model = no dump valve
B model = with dump valve
G model = direct proportionally controlled

 

 

Description

The HC6 is a high flow unit which is capable of up to 11 l/min flow on the high pressure end. Like other miniBOOSTER models, the HC6 raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Relative to its flow capability, the HC6 is a compact unit weighing only 9.5 kg.

Flow Rates

Intensification factor
i

Max. outlet flow
l/min

Max. inlet flow
l/min

1.3

3.1

50.0

1.5

2.5

50.0

1.9

2.0

50.0

2.5

13.0

70.0

3.3

11.0

70.0

4.0

9.0

70.0

4.9

7.0

70.0

6.3

5.5

70.0

8.2

4.5

70.0

Dimensions

Functions

The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the check valves KV1, KV2 and DV to the high pressure side H. In this condition maximum flow through the booster is achieved giving a fast forward function.

When pump pressure is reached on the high pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when end pressure on high pressure side H is reached. If there is a pressure drop on the high pressure side due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.

Function Diagram

Connection types

Connection

IN / R

H

1

1/2" BSP

1/2" BSP

2

3/4-16" UNF

3/4-16" UNF

Max. tightening torque BSP

 

IN / R

H

 

1/2" BSP

1/2" BSP

  with steel washer

13.0 da/Nm

13.0 da/Nm

  with aluminium washer

7.0 da/Nm

  with cutting edge

13.0 da/Nm

13.0 da/Nm

Max. tightening torque UNF

 

IN / R

H

 

3/4-16" UNF

  3/4-16" UNF

  with o-ring

3.5 da/Nm

6.0 da/Nm

 

Fluids and materials

Please see General Specifications

Ordering a HC6

Ordering example of a HC6 with i = 4.0, DV incorporated and BSP connections: HC6 - 4.0 - B - 1

Model

 

Intensification, i

 

Dump Valve

 

Connections

HC6


 your selection...


 your selection...


 your selection...

             
 

see flow rate table

 

A = (no) / A model

 

1

 

B = (yes) / B model

2

G = (proportional) / G model



Other Product In Group "miniBOOSTER (29)"