E-Catalog > HALS HANSUNG PRECISION > HALS Lube Pump
Product Detail :
Lube Pump
HMGP 303 & 303D
Internal Control Fixed Quantity Oil Supply Pump

Model

Feature
- A gear type volume pump that allows precise delivery across a wide range of viscosities.
- It can be applied to long distances of more than 20m, and can also be used in small, large machine tools and high-precision machines.
- To make full use of the fixed quantity oil supply system, the HMV series needs to be used for the valve.
- It has an internal control, and therefore does not require separate control devices.
- It has a built-in ullage decrease detector. (Float switch)
PUMP SPEC
PUMP SPEC | |||
---|---|---|---|
MODEL NAME | HMGP-303 | HMGP-303D | |
PUMP TYPE | GEAR PUMP | ||
DISCHARGE PRESSURE | 17kg/cm² | ||
PRESSURE GAUGE | 0~35kg/cm² | ||
USING OIL | 32~220(cSt) | ||
FILTER | 80 Mesh | ||
TANK CAPACITY | 4Liter | 2Liter | |
DISCHARGE AMOUNT | 150cc/min | ||
INTERVAL TIME | 3~120min | 3~30 / 30~120min | |
FLOAT S/W | Contact type A contact (NO) | ||
ON at Low level | |||
PRESSURE S/W | N/A | ||
OIL SUPPLY CONTROL DEVICE | Internal control | ||
MOTOR SPEC | |||
INPUT | 80W | ||
PHASE | 1Ø | ||
VOLTAGE | 110V | 200V | 220V | ||
CURRENT | 1.8A/1.24A | 1.0A | 1.35A/0.85A | ||
FREQUENCY | 50/60Hz | ||
PACKING SPEC | |||
PACKING SIZE(cm) | 36(W) x 17.5(L) x 30.5(D) | 15(W) x 18(L) x 26(D) | |
WEIGHT(kg) | PUMP | 4 | 3 |
PACKING | 4.5 | 3.5 |
Components


External Figure


Operating Guide

- The pump operates once power is connected and electricity is supplied. You can set the pause time using the Interval ① on the front of the pump, and discharge ② to set the operating time (seconds). Afterwards, the pump will repeatedly operate and pause
- Minimum pause time of the pump is 3 minutes, and the minimum discharge time can be set to 3 seconds.
- When operating the pump, the DIS, lamp ③ switches on, and during the pause, the INT lamp ④ switches on. When ullage inside the tank decreases, the EMG, lamp ⑤ switches on. When ullage inside the tank decreases, the EMG lamp ⑤ switches on.
- The MAN. button ⑥ can be used for test operations and to let air out from the pipes
(But, do not operate more than 5 minutes, as it can cause Motor damage) - The pump is set at 17kg/cm when released from the factory, but this may differ depending on the changes in the viscosities of the oils used (oil viscosity, surrounding temperature).
Hydraulic circuit drawing

Wiring Diagram

HMGP 6N & 6C
Internal Control or External Control Proportional Oil Supply Pump

Model

Feature
- It is the most suitable pump for proportional oil supply, and can be applied to a wide range of industrial fields
- It has a simple structure and excellent durability
- Internal control (6N) or External control (6C) are available.
- It is equipped with a ullage decrease detector tovincrease reliability.
- It is equipped with a dustproof device, and can be used in presses that are subjected to vibrations and impacts.
- A line filter and a drain filter are used side by side, allowing oil reuse.
- To fully utilize the proportional oil supply system, you must use the HJB series valve.
PUMP SPEC
PUMP SPEC | |||
---|---|---|---|
MODEL NAME | HMGP-6N | HMGP-6C | |
PUMP TYPE | GEAR PUMP | ||
DISCHARGE PRESSURE | 16kg/cm² | ||
PRESSURE GAUGE | 0~35kg/cm² | ||
USING OIL | 32~220(cSt) | ||
FILTER | 80 Mesh | ||
TANK CAPACITY | 4Liter | ||
DISCHARGE AMOUNT | 4~113cc | 100cc/min | |
INTERVAL TIME | 1~120min / 1~60min / 2~32Hr | External control | |
FLOAT S/W | Contact type A contact (NO) | ||
ON at Low level | |||
OIL RECOVERY | Attachable | ||
OIL WARNING | BUZZER/LAMP | ||
MOTOR SPEC | |||
INPUT | 50W | ||
PHASE | 1Ø | ||
VOLTAGE | 110V | 200V | 220V | ||
CURRENT | 1.40A/0.95A | 0.60A | 0.75A/0.50A | ||
FREQUENCY | 50/60Hz | ||
PACKING SPEC | |||
PACKING SIZE(cm) | 35(W) x 15(L) x 30(D) | ||
WEIGHT(kg) | PUMP | 5 | |
PACKING | 6 |
Components


External Figure

Operating Guide

- The pump operates once power is connected and electricity is supplied. You can set the pause time using the Interval ① on the front of the pump, and discharge ② to set the operating time (seconds). Afterwards, the pump will repeatedly operate and pause.
- Minimum pause time of the pump is 1 minute, and the lowest discharge can be set to 4cc.
- When operating the pump, the DIS, lamp ③ switches on, and during the pause, the INT, lamp ④ switches on. When ullage inside the tank decreases, the EMG lamp ⑤ switches on.
- The MAN, button ⑥ can be used for test operations and to let air out from the pipes. (But, do not operate more than 5 minutes, as it can cause motor damage.)
- The pump is set at 16kg/cm when released from the factory, but this may differ depending on the changes in the viscosities of the oils used soil viscosity, surrounding temperature).
Hydraulic circuit drawing

Wiring Diagram
-
HMGP 303 & 303D
-
HMGP 303S & 303M
-
HMGP 205S
-
HMGP 205C
-
HMGP 6N & 6C
-
HMGP 105N series
-
HMGP 105D series
-
HALS 33
-
HMGP 6A & 6MA
-
HMV series
-
340 series
-
350 series
-
HMLV series
-
MIXING VALVE
-
Valve series
HMGP 205S
External Control Fixed Quantity Oil Supply Pump

Model

Feature
- A large capacity fixed quantity oil supply pump suitable for multiple oil supply sites and large machines
- An external control type that allows various pump controls according to operational environments.
- Main drive parts of the pump are inside the AL body to ensure superior durability.
- The pump part can be used separately, and can be attached to other tanks for use.
PUMP SPEC
PUMP SPEC | |||
---|---|---|---|
MODEL NAME | HMGP-205S | ||
PUMP TYPE | GEAR PUMP | ||
DISCHARGE PRESSURE | 15~30kg/cm² | ||
PRESSURE GAUGE | 0~35kg/cm² | ||
USING OIL | 32~220(cSt) | ||
FILTER | 80 Mesh | ||
TANK CAPACITY | 5Liter | ||
DISCHARGE AMOUNT | 300cc/min | ||
FLOAT S/W | Contact type A contact (NO) | ||
Operation pressure : 12 ± 1 bar ON | |||
OIL SUPPLY CONTROL DEVICE | External control | ||
MOTOR SPEC | |||
INPUT | 60W | ||
PHASE | 1Ø | ||
VOLTAGE | 200V | 220V | ||
CURRENT | 1.0A | 1.35A/0.85A | ||
FREQUENCY | 50/60Hz | ||
PACKING SPEC | |||
PACKING SIZE(cm) | 35(W) x 18(L) x 30(D) | ||
WEIGHT(kg) | PUMP | 5 | |
PACKING | 5.5 |
Components


External Figure


Operating Guide
- It does not have a separate control device, and the pump operates automatically once power is connected and electricity is supplied. The pause and operation times can be set in the same way as for HMGP-303.
- Minimum pause time of the pump is 4 minutes, and the pause time needs to be set at 4 times the operation time.
※ Time needs to be followed for precise fixed quantity valve operation. - This motor is not a continuous operation pump, so please refrain from operating for more than 5 minutes
- The pump is set at 17kg/cm when released from the factory, but this may differ depending on the changes in the viscosities of the oils used (oil viscosity, surrounding temperature).
- The pressure switch can operate the pump and detect whether or not the set pressure has been reached within a given time, and send contact signals to the machine control device during normal operation to check for errors, (option)
- The pump is used separately. It can be attached freely inside the tank for use.
Hydraulic circuit drawing

Wiring Diagram


HMGP 303 & 303D
Internal Control Fixed Quantity Oil Supply Pump

Model

Feature
- A gear type volume pump that allows precise delivery across a wide range of viscosities.
- It can be applied to long distances of more than 20m, and can also be used in small, large machine tools and high-precision machines.
- To make full use of the fixed quantity oil supply system, the HMV series needs to be used for the valve.
- It has an internal control, and therefore does not require separate control devices.
- It has a built-in ullage decrease detector. (Float switch)
PUMP SPEC
PUMP SPEC | |||
---|---|---|---|
MODEL NAME | HMGP-303 | HMGP-303D | |
PUMP TYPE | GEAR PUMP | ||
DISCHARGE PRESSURE | 17kg/cm² | ||
PRESSURE GAUGE | 0~35kg/cm² | ||
USING OIL | 32~220(cSt) | ||
FILTER | 80 Mesh | ||
TANK CAPACITY | 4Liter | 2Liter | |
DISCHARGE AMOUNT | 150cc/min | ||
INTERVAL TIME | 3~120min | 3~30 / 30~120min | |
FLOAT S/W | Contact type A contact (NO) | ||
ON at Low level | |||
PRESSURE S/W | N/A | ||
OIL SUPPLY CONTROL DEVICE | Internal control | ||
MOTOR SPEC | |||
INPUT | 80W | ||
PHASE | 1Ø | ||
VOLTAGE | 110V | 200V | 220V | ||
CURRENT | 1.8A/1.24A | 1.0A | 1.35A/0.85A | ||
FREQUENCY | 50/60Hz | ||
PACKING SPEC | |||
PACKING SIZE(cm) | 36(W) x 17.5(L) x 30.5(D) | 15(W) x 18(L) x 26(D) | |
WEIGHT(kg) | PUMP | 4 | 3 |
PACKING | 4.5 | 3.5 |
HMGP 303S & 303M
External Control Fixed Quantity Oil Supply Pump

Model

Feature
- A highly reliable externally controlled fixed quantity oil supply pump.
- It is used across a wide range of fields, and is especially suitable as a fixed quantity oil supply pump for high-precision, large machine tools.
- The pump's main drive connection parts are made of single die casting pieces to ensure excellent durability.
- An external control type that allows free pump control.
- It has a built-in ullage decrease detector and a pressure decrease detector.
PUMP SPEC
PUMP SPEC | |||
---|---|---|---|
MODEL NAME | HMGP-303S | HMGP-303M | |
PUMP TYPE | GEAR PUMP | ||
DISCHARGE PRESSURE | 17kg/cm² | ||
PRESSURE GAUGE | 0~35kg/cm² | ||
USING OIL | 32~220(cSt) | ||
FILTER | 80 Mesh | ||
TANK CAPACITY | 4Liter | 2Liter | |
DISCHARGE AMOUNT | 150cc/min | ||
FLOAT S/W | Contact type A contact (NO) | ||
Operation pressure : 12 ± 1 bar ON | |||
OIL SUPPLY CONTROL DEVICE | External control | ||
MOTOR SPEC | |||
INPUT | 80W | ||
PHASE | 1Ø | ||
VOLTAGE | 110V | 200V | 220V | ||
CURRENT | 1.8A/1.24A | 1.0A | 1.35A/0.85A | ||
FREQUENCY | 50/60Hz | ||
PACKING SPEC | |||
PACKING SIZE(cm) | 36(W) x 18(L) x 31(D) | 23(W) x 14(L) x 28(D) | |
WEIGHT(kg) | PUMP | 4 | 3.5 |
PACKING | 4.5 | 4 |
HMGP 205S
External Control Fixed Quantity Oil Supply Pump

Model

Feature
- A large capacity fixed quantity oil supply pump suitable for multiple oil supply sites and large machines
- An external control type that allows various pump controls according to operational environments.
- Main drive parts of the pump are inside the AL body to ensure superior durability.
- The pump part can be used separately, and can be attached to other tanks for use.
PUMP SPEC
PUMP SPEC | |||
---|---|---|---|
MODEL NAME | HMGP-205S | ||
PUMP TYPE | GEAR PUMP | ||
DISCHARGE PRESSURE | 15~30kg/cm² | ||
PRESSURE GAUGE | 0~35kg/cm² | ||
USING OIL | 32~220(cSt) | ||
FILTER | 80 Mesh | ||
TANK CAPACITY | 5Liter | ||
DISCHARGE AMOUNT | 300cc/min | ||
FLOAT S/W | Contact type A contact (NO) | ||
Operation pressure : 12 ± 1 bar ON | |||
OIL SUPPLY CONTROL DEVICE | External control | ||
MOTOR SPEC | |||
INPUT | 60W | ||
PHASE | 1Ø | ||
VOLTAGE | 200V | 220V | ||
CURRENT | 1.0A | 1.35A/0.85A | ||
FREQUENCY | 50/60Hz | ||
PACKING SPEC | |||
PACKING SIZE(cm) | 35(W) x 18(L) x 30(D) | ||
WEIGHT(kg) | PUMP | 5 | |
PACKING | 5.5 |
HMGP 205C
External Control Continuous Oil Supply Pump

Model

Feature
- It can be applied to large capacity proportional oil supply systems
- It is suitable for lubricating oil supply devices, as well as for a small number of lubricating oil recovery devices.
- An externally controlled pump, and is capable of various applications according to the users' operational environments.
- It is equipped with an ullage decrease detector.
- Applied applied broadly from HJB series to HJC series.(Continuous type)
PUMP SPEC
PUMP SPEC | |||
---|---|---|---|
MODEL NAME | HMGP-205C | ||
PUMP TYPE | GEAR PUMP | ||
DISCHARGE PRESSURE | 5~10kg/cm² | ||
PRESSURE GAUGE | 0~35kg/cm² | ||
USING OIL | 32~220(cSt) | ||
FILTER | 80 Mesh | ||
TANK CAPACITY | 5Liter | ||
DISCHARGE AMOUNT | 100cc/min | ||
INTERVAL TIME | CONSTANT | ||
FLOAT S/W | Contact type A contact (NO) | ||
ON at Low level | |||
OIL SUPPLY CONTROL DEVICE | External control | ||
OIL WARNING | Output at Contact point | ||
MOTOR SPEC | |||
INPUT | 25W | ||
PHASE | 1Ø | ||
VOLTAGE | 110V | 220V | ||
CURRENT | 0.46A | 0.21A | ||
FREQUENCY | 50/60Hz | ||
PACKING SPEC | |||
PACKING SIZE(cm) | 35(W) x 18(L) x 30(D) | ||
WEIGHT(kg) | PUMP | 7 | |
PACKING | 8 |
HMGP 6N & 6C
Internal Control or External Control Proportional Oil Supply Pump

Model

Feature
- It is the most suitable pump for proportional oil supply, and can be applied to a wide range of industrial fields
- It has a simple structure and excellent durability
- Internal control (6N) or External control (6C) are available.
- It is equipped with a ullage decrease detector tovincrease reliability.
- It is equipped with a dustproof device, and can be used in presses that are subjected to vibrations and impacts.
- A line filter and a drain filter are used side by side, allowing oil reuse.
- To fully utilize the proportional oil supply system, you must use the HJB series valve.
PUMP SPEC
PUMP SPEC | |||
---|---|---|---|
MODEL NAME | HMGP-6N | HMGP-6C | |
PUMP TYPE | GEAR PUMP | ||
DISCHARGE PRESSURE | 16kg/cm² | ||
PRESSURE GAUGE | 0~35kg/cm² | ||
USING OIL | 32~220(cSt) | ||
FILTER | 80 Mesh | ||
TANK CAPACITY | 4Liter | ||
DISCHARGE AMOUNT | 4~113cc | 100cc/min | |
INTERVAL TIME | 1~120min / 1~60min / 2~32Hr | External control | |
FLOAT S/W | Contact type A contact (NO) | ||
ON at Low level | |||
OIL RECOVERY | Attachable | ||
OIL WARNING | BUZZER/LAMP | ||
MOTOR SPEC | |||
INPUT | 50W | ||
PHASE | 1Ø | ||
VOLTAGE | 110V | 200V | 220V | ||
CURRENT | 1.40A/0.95A | 0.60A | 0.75A/0.50A | ||
FREQUENCY | 50/60Hz | ||
PACKING SPEC | |||
PACKING SIZE(cm) | 35(W) x 15(L) x 30(D) | ||
WEIGHT(kg) | PUMP | 5 | |
PACKING | 6 |
Components


External Figure

Operating Guide

- The pump operates once power is connected and electricity is supplied. You can set the pause time using the Interval ① on the front of the pump, and discharge ② to set the operating time (seconds). Afterwards, the pump will repeatedly operate and pause.
- Minimum pause time of the pump is 1 minute, and the lowest discharge can be set to 4cc.
- When operating the pump, the DIS, lamp ③ switches on, and during the pause, the INT, lamp ④ switches on. When ullage inside the tank decreases, the EMG lamp ⑤ switches on.
- The MAN, button ⑥ can be used for test operations and to let air out from the pipes. (But, do not operate more than 5 minutes, as it can cause motor damage.)
- The pump is set at 16kg/cm when released from the factory, but this may differ depending on the changes in the viscosities of the oils used soil viscosity, surrounding temperature).
HMGP 105N series
Internal & External Control Proportional Oil Supply Pump

Model

Feature
- It is the most suitable pump for proportional oil supply. It can be applied to a wide range of industrial machines.
- The compact design reduces installation space limitations, and the simple use means easy installation and repairs
- During reduced ulage, selections can be made to suit user environments using contact output and buzzer.
- Every model is attached with a suction filter to prevent the entry of alien substances in the pipe.
- Increased pressure settings are available according to operational environments.
- Internal control type(HMGP-105N, 105M, 103) and External control type(HMGP-105C) can be used.
PUMP SPEC
PUMP SPEC | |||||
---|---|---|---|---|---|
MODEL NAME | HMGP-105N | HMGP-105M | HMGP-103 | HMGP-105C | |
PUMP TYPE | GEAR PUMP | ||||
DISCHARGE PRESSURE | 8kg/cm² | ||||
USING OIL | 32~220(cSt) | ||||
FILTER | 80 Mesh | ||||
TANK CAPACITY | 2Liter | ||||
DISCHARGE AMOUNT | S : 4~45cc/min / L : 4~80cc/min | 100cc/min | |||
INTERVAL TIME | S : 3~30min / L : 30~120min | External control | |||
FLOAT S/W | - | Contact type A contact (NO) | |||
- | ON at Low level | ||||
OIL WARNING | Order specification | BUZZER | Optput at Contact point | ||
MOTOR SPEC | |||||
INPUT | 50W | ||||
PHASE | 1Ø | ||||
VOLTAGE | 110V | 200V | 220V | ||||
CURRENT | 1.40A/0.95A | 0.60A | 0.75A/0.5A | ||||
FREQUENCY | 50/60Hz | ||||
PACKING SPEC | |||||
PACKING SIZE(cm) | 15(W) x 18(L) x 26(D) | ||||
WEIGHT(kg) | PUMP | 2.4 | |||
PACKING | 2.5 |
HMGP 105D series
Internal & External Control Proportional Oil Supply Pump

Model

Feature
- A product identical in shape to HMGP-105, but with the control box made out of die casting AL to ensure superior durability and resistance against external impacts.
- The main parts of the pump are integrated to ensure easy repairs and maintenance.
- Internal control type(HMGP-105D) and External control type(HMGP-105DC, 105W) can be used.
PUMP SPEC
PUMP SPEC | ||||
---|---|---|---|---|
MODEL NAME | HMGP-105D | HMGP-105DC | HMGP-105W | |
PUMP TYPE | GEAR PUMP | |||
DISCHARGE PRESSURE | 8kg/cm² | |||
USING OIL | 32~220(cSt) | |||
FILTER | 80 Mesh | |||
TANK CAPACITY | 2Liter | |||
DISCHARGE AMOUNT | 4~45 / 4~80cc/min | 100cc/min | ||
INTERVAL TIME | 3~30 / 300~120min | External control | ||
FLOAT S/W | Contact type A contact (NO) | |||
ON at Low level | ||||
PRESSURE S/W | - | Contact type A contact(NO) | ||
- | Operation pressure 1.5 ± 0.2 bar ON | |||
MOTOR SPEC | ||||
INPUT | 50W | |||
PHASE | 1Ø | |||
VOLTAGE | 110V | 200V | 220V | |||
CURRENT | 1.40A/0.95A | 0.60A | 0.75A/0.50A | |||
FREQUENCY | 50/60Hz | |||
PACKING SPEC | ||||
PACKING SIZE(cm) | 15(W) x 18(L) x 26(D) | |||
WEIGHT(kg) | PUMP | 2.9 | ||
PACKING | 2.3 |
Components


External Figure


Operating Guide

- The pump operates once power is connected and electricity is supplied. You can set the pause time using the Interval ① on the front of the pump, and discharge ② to set the operating time (seconds). Afterwards, the pump will repeatedly operate and pause
- Minimum pause time of the pump is 3 minutes, and the discharge time can be set to 30c (HMGP-105D)
- When operating the pump, the DIS, lamp ③ switches on, and during the pause, the INT, lamp ④ switches on
- he MAN ⑤ button can be used for test operations and to let air out from the pipes. (But, do not operate more than 5 minutes, as it can cause motor damage.)
- The pump is set at 8kg/cm' when released from the factory, but this may differ depending on the changes in the viscosities of the oils used (ail viscosity, surrounding temperature).
Hydraulic circuit drawing

Wiring Diagram

HALS 33
Piston Manual Pump

Model

Feature
A piston manual pump with a specially processed cylinder interior to raise the pump discharge pressure to 7kg/cm2 for a smooth supply of lubricating oil. Also compact and lightweight, requiring little installation space, and is therefore very economical.
PUMP SPEC
PUMP SPEC | ||
---|---|---|
MODEL NAME | HALS-33 | |
PUMP TYPE | PISTON | |
DISCHARGE PRESSURE | 7kg/cm² | |
TANK CAPACITY | 1Liter | |
DISCHARGE AMOUNT | 7cc/st | |
PACKING SPEC | ||
PACKING SIZE(cm) | 25(W) x 18(L) x 23(D) | |
WEIGHT(kg) | PUMP | 1 |
PACKING | 2 |
External Figure


HMGP 6A & 6MA
Air Drive Fixed Quantity / Proportional Oil Supply Pump

Model

Feature
- HMGP-6A
- Easy lubricating oil supply through supplying compressed air
- The pump drive parts are produced with die casting molds for superior durability
- Easy control bar operation for free control of the quantity of discharge
- The attached suction filter on every model prevents suction of foreign substances - HMGP-6MA
- A fixed quantity oil supply pump used with the HMV Series fixed quantity valve
- It is capable of long distance delivery.
PUMP SPEC
PUMP SPEC | |||
---|---|---|---|
MODEL NAME | HMGP-6A | HMGP-6MA | |
DISCHARGE PRESSURE | 10kg/cm² | 20kg/cm² | |
USING OIL | 32~220(cSt) | ||
FILTER | 80 Mesh | ||
TANK CAPACITY | 2Liter | ||
DISCHARGE AMOUNT | 0~6cc/st | 6cc/st | |
PACKING SPEC | |||
PACKING SIZE(cm) | 15(W) x 18(L) x 26(D) | ||
WEIGHT(kg) | PUMP | 1 | |
PACKING | 2 |
External Figure


Operating Guide

- HMGP-6A Oil quantity adjustment The oil quantity can easily be adjusted by turning the control bar
- The pump operation time needs to be adjusted by attaching a Sol V/V at the air adulteration section.