Pump Spec
MOTOR | PUMP | ||||||||
---|---|---|---|---|---|---|---|---|---|
OUTPUT(W) | FREQUENCY(Hz) | VOLTAGE(V) | CURRENT(A) | PHASE | POLES | TOTAL HEAD(m) | DIS. VOL( l /min) | PIPE SIZE(PT) | |
HCP-1100EHMF(S) | 1100 | 50 | 220 380 |
4.3 2.5 |
3 | 2 | 30 | 30 | 3/4" |
60 | 200/220 380 |
5.1 3.0 |
45 | ||||||
HCP-1800EHMF(S) | 1800 | 50 | 200 380 |
6.5 3.8 |
3 | 2 | 50 | 30 | 3/4" |
60 | 200/220 380 |
7.0 4.1 |
70 | ||||||
HCP-2500EHMF(S) | 2500 | 50 | 200 380 |
8.7 5.2 |
3 | 2 | 70 | 30 | 3/4" |
60 | 200/220 380 |
9.7 5.6 |
100 | ||||||
HCP-4000EHMF(S) | 4000 | 50 | 200 380 |
16.0 8.5 |
3 | 2 | 90 | 20 | 3/4" |
60 | 200/220 380 |
18.0 10.7 |
130 |
Packing Spec
MODEL NAME | PACKING SIZE(cm) | WEIGHT(kg) | |
---|---|---|---|
PUMP | PACKING | ||
HCP-1100EHMF | 50(W) x 30(L) x 27(D) | 26 | 27 |
HCP-1100EHMFS | 25 | 27 | |
HCP-1800EHMFS | 28 | 29 | |
HCP-1800EHMF | 63(W) x 29(L) x 30(D) | 29 | 30 |
HCP-2500EHMF | 39 | 40 | |
HCP-2500EHMFS | 38 | 39 | |
HCP-4000EHMF | 45 | 46 | |
HCP-4000EHMFS | 44 | 45 |
Performance Curve

* When using non water-soluble cutting fluid, Viscosity must be under 32cSt. Pump performance (pressure and quantity) will decrease compared to water-solube cutting fluid.

External Figure


Dimension
ØD | L1 | L2 | L3 | L4 | L5 | L6 | L7 | L8 | L9 | L10 | L11 | PE(PT) | TL | R1 | LA | N-ØB | PL1 | PL2 | M | ML | PK(PF) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HCP-1100EHMF | 169 | 13 | 25 | 179 | 272.5 | 136 | 97 | 219.5 | 164 | 68 | 20 | 115 | 3/4" | 451 | 170 | 215 | 4-12 | 119 | 100 | 200 | 115 | 1½" |
HCP-1100EHMFS | 162.5 | 13 | 25 | 154 | 272.5 | 111 | 97 | 219.5 | 164 | 68 | 20 | 90 | 3/4" | 426 | 170 | 215 | 4-12 | 119 | 100 | 200 | 115 | 1½" |
HCP-1800EHMF | 86 | 13 | 25 | 243 | 280 | 199 | 97 | 227 | 164 | 83 | 20 | 178 | 3/4" | 475 | 170 | 215 | 4-12 | 137 | 100 | 200 | 115 | 1½" |
HCP-1800EHMFS | 186 | 13 | 25 | 195 | 280 | 151 | 97 | 227 | 164 | 83 | 20 | 130 | 3/4" | 475 | 170 | 215 | 4-12 | 137 | 100 | 200 | 115 | 1½" |
HCP-2500EHMF | 186 | 13 | 25 | 290 | 306 | 246 | 97 | 253 | 164 | 83 | 20 | 224 | 3/4" | 596 | 170 | 215 | 4-12 | 137 | 100 | 200 | 115 | 1½" |
HCP-2500EHMFS | 186 | 13 | 25 | 250 | 306 | 206 | 97 | 253 | 164 | 83 | 20 | 184 | 3/4" | 556 | 170 | 215 | 4-12 | 137 | 100 | 200 | 115 | 1½" |
HCP-4000EHMF | 186 | 13 | 25 | 359 | 326 | 316 | 97 | 273 | 170 | 95 | 20 | 302 | 3/4" | 687 | 170 | 215 | 4-12 | 154 | 100 | 200 | 115 | 1½" |
HCP-4000EHMFS | 186 | 13 | 25 | 312 | 326 | 269 | 97 | 273 | 170 | 95 | 20 | 255 | 3/4" | 638 | 170 | 215 | 4-12 | 154 | 100 | 200 | 115 | 1½" |
HCP EHMF(S) series

Model

Feature
- HCP-□HMF(S)
· Identical pump spray areas make exchanges easy.
· Prolonged idling is prohibited due to the installed mechnical seal. (Idling for more than 10 seconds is prohibited)
· It is produced with a single-unit shaft, which increases durability and makes management easy.
- HCP-□EHMF(S)
· High efficiency motor is installed in HCP-HMF(S) Type
· Excellent electricity savings and high economic return on investment through optimized efficiency
· Increase in life-time use through slow temperature increase and use of highly energy-efficient energy materials.
· Acquired high efficiency energy equipment mark.
Pump Spec
MOTOR | PUMP | ||||||||
---|---|---|---|---|---|---|---|---|---|
OUTPUT(W) | FREQUENCY(Hz) | VOLTAGE(V) | CURRENT(A) | PHASE | POLES | TOTAL HEAD(m) | DIS. VOL( l /min) | PIPE SIZE(PT) | |
HCP-1100EHMF(S) | 1100 | 50 | 220 380 |
4.3 2.5 |
3 | 2 | 30 | 30 | 3/4" |
60 | 200/220 380 |
5.1 3.0 |
45 | ||||||
HCP-1800EHMF(S) | 1800 | 50 | 200 380 |
6.5 3.8 |
3 | 2 | 50 | 30 | 3/4" |
60 | 200/220 380 |
7.0 4.1 |
70 | ||||||
HCP-2500EHMF(S) | 2500 | 50 | 200 380 |
8.7 5.2 |
3 | 2 | 70 | 30 | 3/4" |
60 | 200/220 380 |
9.7 5.6 |
100 | ||||||
HCP-4000EHMF(S) | 4000 | 50 | 200 380 |
16.0 8.5 |
3 | 2 | 90 | 20 | 3/4" |
60 | 200/220 380 |
18.0 10.7 |
130 |
Packing Spec
MODEL NAME | PACKING SIZE(cm) | WEIGHT(kg) | |
---|---|---|---|
PUMP | PACKING | ||
HCP-1100EHMF | 50(W) x 30(L) x 27(D) | 26 | 27 |
HCP-1100EHMFS | 25 | 27 | |
HCP-1800EHMFS | 28 | 29 | |
HCP-1800EHMF | 63(W) x 29(L) x 30(D) | 29 | 30 |
HCP-2500EHMF | 39 | 40 | |
HCP-2500EHMFS | 38 | 39 | |
HCP-4000EHMF | 45 | 46 | |
HCP-4000EHMFS | 44 | 45 |
Performance Curve

* When using non water-soluble cutting fluid, Viscosity must be under 32cSt. Pump performance (pressure and quantity) will decrease compared to water-solube cutting fluid.

External Figure


Dimension
ØD | L1 | L2 | L3 | L4 | L5 | L6 | L7 | L8 | L9 | L10 | L11 | PE(PT) | TL | R1 | LA | N-ØB | PL1 | PL2 | M | ML | PK(PF) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HCP-1100EHMF | 169 | 13 | 25 | 179 | 272.5 | 136 | 97 | 219.5 | 164 | 68 | 20 | 115 | 3/4" | 451 | 170 | 215 | 4-12 | 119 | 100 | 200 | 115 | 1½" |
HCP-1100EHMFS | 162.5 | 13 | 25 | 154 | 272.5 | 111 | 97 | 219.5 | 164 | 68 | 20 | 90 | 3/4" | 426 | 170 | 215 | 4-12 | 119 | 100 | 200 | 115 | 1½" |
HCP-1800EHMF | 86 | 13 | 25 | 243 | 280 | 199 | 97 | 227 | 164 | 83 | 20 | 178 | 3/4" | 475 | 170 | 215 | 4-12 | 137 | 100 | 200 | 115 | 1½" |
HCP-1800EHMFS | 186 | 13 | 25 | 195 | 280 | 151 | 97 | 227 | 164 | 83 | 20 | 130 | 3/4" | 475 | 170 | 215 | 4-12 | 137 | 100 | 200 | 115 | 1½" |
HCP-2500EHMF | 186 | 13 | 25 | 290 | 306 | 246 | 97 | 253 | 164 | 83 | 20 | 224 | 3/4" | 596 | 170 | 215 | 4-12 | 137 | 100 | 200 | 115 | 1½" |
HCP-2500EHMFS | 186 | 13 | 25 | 250 | 306 | 206 | 97 | 253 | 164 | 83 | 20 | 184 | 3/4" | 556 | 170 | 215 | 4-12 | 137 | 100 | 200 | 115 | 1½" |
HCP-4000EHMF | 186 | 13 | 25 | 359 | 326 | 316 | 97 | 273 | 170 | 95 | 20 | 302 | 3/4" | 687 | 170 | 215 | 4-12 | 154 | 100 | 200 | 115 | 1½" |
HCP-4000EHMFS | 186 | 13 | 25 | 312 | 326 | 269 | 97 | 273 | 170 | 95 | 20 | 255 | 3/4" | 638 | 170 | 215 | 4-12 | 154 | 100 | 200 | 115 | 1½" |
HCP EMF(S) series

Model

Feature
- HCP-□MF(S)
· It can be applied when large quantities of oil are required
· The motor part is detached to reduce the transfer of heat
· A submerged bottom section suction pump that must be kept at least 30mm above the tank floor.
· The pump part is detached to reduce the entry of oil into the motor.
- HCP-□EMF(S)
· High efficiency motor is installed in HCP-MF(S) Type
· Excellent electricity savings and high economic return on investment through optimized efficiency
· Increase in life-time use through slow temperature increase and use of highly energy-efficient energy materials
· Acquired high efficiency energy equipment mark (IE3)
Pump Spec
MOTOR | PUMP | ||||||||
---|---|---|---|---|---|---|---|---|---|
OUTPUT(W) | FREQUENCY(Hz) | VOLTAGE(V) | CURRENT(A) | PHASE | POLES | TOTAL HEAD(m) | DIS. VOL( l /min) | PIPE SIZE(PT) | |
HCP-1100EMF(S) | 1100 | 50 | 200 380 |
4.2 2.5 |
3 | 2 | 6.5 | 200 | 1¼"(1½") |
60 | 200/220 380 |
4.8 2.8 |
10 | ||||||
HCP-1800EMF | 1800 | 50 | 200 380 |
6.6 3.8 |
3 | 2 | 20 | 100 | 1½" |
60 | 200/220 380 |
7.0 4.1 |
30 | ||||||
HCP-2500EMF | 2500 | 50 | 200 380 |
8.8 5.2 |
3 | 2 | 30 | 100 | 1½" |
60 | 200/220 380 |
10.0 5.6 |
45 | ||||||
HCP-4000EMF | 4000 | 50 | 200 380 |
16.0 8.5 |
3 | 2 | 50 | 100 | 1½" |
60 | 200/220 380 |
18.0 10.7 |
70 |
Packing Spec
MODEL NAME | PACKING SIZE(cm) | WEIGHT(kg) | |
---|---|---|---|
PUMP | PACKING | ||
HCP-1100EMF | 59(W) x 25(L) x 29(D) | 28 | 29 |
HCP-1100EMFS | 27 | 28 | |
HCP-1800EMF | 63(W) x 29(L) x 30(D) | 31 | 32 |
HCP-2500EMF | 35 | 36 | |
HCP-4000EMF | 80(W) x 27(L) x 31(D) | 45 | 46 |
Performance Curve

* When using non water-soluble cutting fluid, Viscosity must be under 32cSt. Pump performance (pressure and quantity) will decrease compared to water-solube cutting fluid.

External Figure


Dimension
ØD | L1 | L2 | L3 | L4 | L5 | L6 | L7 | L8 | L9 | L10 | L11 | PE(PT) | TL | R1 | LA | N-ØB | PL1 | PL2 | M | ML | PK(PF) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HCP-1100EMF | 169 | 12 | 40 | 245 | 310.5 | 186 | 150 | 220 | 166 | 67.6 | 20 | 185 | 1½" 1¼" | 555 | 170 | 215 | 4-12 | 119 | 95 | 190 | 105 | 2" |
HCP-1100EMFS | 169 | 12 | 40 | 210 | 310.5 | 151 | 150 | 220 | 166 | 67.6 | 20 | 150 | 1¼" | 520 | 170 | 215 | 4-12 | 119 | 95 | 190 | 105 | 2" |
HCP-1800EMF | 164 | 12 | 36 | 245 | 317 | 201 | 134 | 227 | 166 | 80 | 20 | 185 | 1½" | 562 | 170 | 215 | 4-12 | 119 | 95 | 190 | 105 | 2" |
HCP-2500EMF | 194 | 12 | 36 | 245 | 343 | 201 | 134 | 253 | 166 | 80 | 20 | 185 | 1½" | 588 | 170 | 215 | 4-12 | 137 | 100 | 200 | 115 | 2" |
HCP-4000EMF | 232 | 12 | 36 | 354 | 377 | 310 | 144 | 277 | 176 | 80 | 20 | 303 | 1½" | 731 | 170 | 215 | 4-12 | 162 | 109 | 218 | 115 | 2" |
HCP EHMF(S) series

Model

Feature
- HCP-□HMF(S)
· Identical pump spray areas make exchanges easy.
· Prolonged idling is prohibited due to the installed mechnical seal. (Idling for more than 10 seconds is prohibited)
· It is produced with a single-unit shaft, which increases durability and makes management easy.
- HCP-□EHMF(S)
· High efficiency motor is installed in HCP-HMF(S) Type
· Excellent electricity savings and high economic return on investment through optimized efficiency
· Increase in life-time use through slow temperature increase and use of highly energy-efficient energy materials.
· Acquired high efficiency energy equipment mark.
Pump Spec
MOTOR | PUMP | ||||||||
---|---|---|---|---|---|---|---|---|---|
OUTPUT(W) | FREQUENCY(Hz) | VOLTAGE(V) | CURRENT(A) | PHASE | POLES | TOTAL HEAD(m) | DIS. VOL( l /min) | PIPE SIZE(PT) | |
HCP-1100EHMF(S) | 1100 | 50 | 220 380 |
4.3 2.5 |
3 | 2 | 30 | 30 | 3/4" |
60 | 200/220 380 |
5.1 3.0 |
45 | ||||||
HCP-1800EHMF(S) | 1800 | 50 | 200 380 |
6.5 3.8 |
3 | 2 | 50 | 30 | 3/4" |
60 | 200/220 380 |
7.0 4.1 |
70 | ||||||
HCP-2500EHMF(S) | 2500 | 50 | 200 380 |
8.7 5.2 |
3 | 2 | 70 | 30 | 3/4" |
60 | 200/220 380 |
9.7 5.6 |
100 | ||||||
HCP-4000EHMF(S) | 4000 | 50 | 200 380 |
16.0 8.5 |
3 | 2 | 90 | 20 | 3/4" |
60 | 200/220 380 |
18.0 10.7 |
130 |
Packing Spec
MODEL NAME | PACKING SIZE(cm) | WEIGHT(kg) | |
---|---|---|---|
PUMP | PACKING | ||
HCP-1100EHMF | 50(W) x 30(L) x 27(D) | 26 | 27 |
HCP-1100EHMFS | 25 | 27 | |
HCP-1800EHMFS | 28 | 29 | |
HCP-1800EHMF | 63(W) x 29(L) x 30(D) | 29 | 30 |
HCP-2500EHMF | 39 | 40 | |
HCP-2500EHMFS | 38 | 39 | |
HCP-4000EHMF | 45 | 46 | |
HCP-4000EHMFS | 44 | 45 |
HCP F(High Pressure) series

Model

Structure
· A submerged-type pump with the same structure as the HCP-F type.
· There are various pump forms according to the different tank depths.
Feature
- It has the same separate motor & pump structure as the HCP-F
- It is used when more pressure than HCP-F is required.
- There is an anti-vortex part at the top of the pump, which allows smooth suction.
- The pump is divided into top section suction or bottom section Suction according to the type of the applied tank.
- HCP-419F,420F are bottom section suction products that have a wide range of suction oil levels.
Pump Spec
MOTOR | PUMP | ||||||||
---|---|---|---|---|---|---|---|---|---|
OUTPUT(W) | FREQUENCY(Hz) |
VOLTAG
E(V) | CURRENT(A) | PHASE | POLES | TOTAL HEAD(m) | DIS. VOL( l /min) | PIPE SIZE(PT) | |
HCP-418F,428F,419F | 400 | 50 | 200 380 |
2.4 1.4 |
3 | 2 | 12 | 40 | 1" |
60 | 200/220 380 |
2.5 1.5 |
16 | ||||||
HCP-618F,628F | 600 | 50 | 200 380 |
2.79 1.61 |
3 | 2 | 12 | 80 | 1" |
60 | 200/220 380 |
3.0 1.73 |
16 |
MOTOR | PACKING SIZE(cm) | WEIGHT(kg) | |
---|---|---|---|
PUMP | PUMP | ||
HCP-418F | 46(W) x 23(L) x 24(D) | 17 | 18 |
HCP-419F | 50(W) x 24(L) x 24(D) | 18 | 19 |
HCP-428F | 58(W) x 22(L) x 23(D) | 18 | 19 |
HCP-618F | 46(W) x 23(L) x 24(D) | 17 | 18 |
HCP-628F | 58(W) x 22(L) x 23(D) | 18 | 19 |
Performance Curve

* When using non water-soluble cutting fluid, Viscosity must be under 32cSt. Pump performance (pressure and quantity) will decrease compared to water-solube cutting fluid.

External Figure


Dimension
ØD | L1 | L2 | L3 | L4 | L5 | L6 | L7 | L8 | PE(PT) | TL | R1 | R2 | LA | N-ØB | PL1 | PL2 | M | ML | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HCP-418F/618F | 137 | 10 | 27 | 180 | 234 | 20 | 122 | 143 | 143 | 1" | 414 | 152 | 150 | 180 | 4-10.5 | 110 | 90 | 180 | 100 |
HCP-419F | 137 | 10 | 27 | 210 | 244 | 20 | 185 | 139 | 139 | 1" | 454 | 152 | 150 | 180 | 4-10.5 | 110 | 90 | 180 | 100 |
HCP-428F/628F | 137 | 10 | 27 | 280 | 234 | 20 | 220 | 143 | 143 | 1" | 514 | 152 | 150 | 180 | 4-10.5 | 110 | 90 | 180 | 100 |
HCP EBMF series

Model

Structure
· Attachment area is same for all HCP-EBMF equipment and therefore flexible in terms of moving.
· Must maintain 30mm distance from the tank's bottomm in the lower part of the pump.
Feature
- A large capacity multi-level pump of large machine tools suitable for cutting oil pump used for washing and shower.
- The motor and the pump have the same shaft but are separated to decrease the flow of oil into the motor
Pump Spec
MOTOR | PUMP | ||||||||
---|---|---|---|---|---|---|---|---|---|
OUTPUT(W) | FREQUENCY(Hz) | VOLTAGE(V) | CURRENT(A) | PHASE | POLES | TOTAL HEAD(m) | DIS. VOL( l /min) | PIPE SIZE(PT) | |
HCP-1800EBMF | 1800 | 50 | 200 380 |
7.5 4.1 |
3 | 2 | 10 | 300 | 2" |
60 | 200/220 380 |
8.5/8.0 4.6 |
12 | 400 | |||||
HCP-2500EBMF | 2500 | 50 | 200 380 |
9.0 5.5 |
3 | 2 | 10 | 400 | 2" |
60 | 200/220 380 |
12.0/11.0 6.4 |
20 | ||||||
HCP-4000EBMF | 4000 | 50 | 200 380 |
16.0 8.5 |
3 | 2 | 10 | 450 | 2" |
60 | 200/220 380 |
18.0/17.0 10.7 |
20 | 500 |