E-Catalog > miniBOOSTER > The HC3-D miniBOOSTER

PAGE VIEW : 5,436

Product Information :

Name :
The HC3-D miniBOOSTER
Category :
  1. เครื่องจักร, อุปกรณ์เกี่ยวกับเครื่องจักร, เครื่องมือกล
Sub - Category :
  1. miniBOOSTER
Brand :
miniBOOSTER
Model :
The HC3-D miniBOOSTER
Product Type :
  1. สินค้า, ผลิตภัณฑ์
Short Description :
The HC3-D miniBOOSTER

Product Detail :

The HC3-D miniBOOSTER

HC3 - D versions: 11 different intensification factors

PIN: 20 – 200 bar (inlet pressure)

PH: 800 bar maximum (outlet pressure)

PRETURN: As low as possible (Return pressure to tank)

Intensification ratios: PH = (PIN – PReturn) i (Intensification)

Mounting: Manifold system miniBOOSTER pattern

Accessories: Pilot operated dump valve available

A model = no dump valve
B model = with dump valve
G model = direct proportionally controlled

 

Description

The HC3 - D is a variant of the HC3, with all ports in one end. The hole pattern is a miniBOOSTER design. It is a compact unit weighing only 1.75 kg.

The HC3 - D has the pilot operated dump valve incorporated as a standard feature. Maximum outlet pressure is 800 bar in standard versions. An adjustment of the outlet pressure is carried out by varying the supplied pressure.

Flow Rates

Intensification factor
i

Max. outlet flow
l/min

Max. inlet flow
l/min

1.2

1.2

8.0

1.5

1.0

8.0

2.0

2.0

12.0

2.8

2.2

13.0

3.2

2.5

15.0

4.0

2.0

14.0

5.0

1.6

14.0

6.6

1.3

13.0

9.0

0.9

13.0

13.0

0.6

12.0

20.0

0.3

12.0

Dimensions

Functions

The basic operation is illustrated in the function diagram. The oil is fed through the connecting plate to the IN port of the HC3-D flowing freely through check valves KV1, KV2 and DV to the high pressure side H.

From the high pressure side H oil is fed to port A on the connecting plate. In this condition maximum flow through the booster is achieved giving a fast forward function. When pump pressure is reached on the high pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when end pressure on high pressure side is reached. If there is a pressure drop on the high pressure side due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.

Function Diagram

Fluids and materials

Please see General Specifications

Ordering a HC3-D

Ordering example of a HC3 - D with i = 4.0, DV incorporated: HC3 - 4.0 - B - D

Model

 

Intensification, i

 

Dump Valve

 

Model

HC3


 your selection...


 your selection...


D

             
 

see flow rate table

 

A = (no) / A model

   
 

B = (yes) / B model

 

G = (proportional) / G model