E-Catalog > miniBOOSTER > The HC2P miniBOOSTER
Product Detail :
The HC2P miniBOOSTER

Booster Pump
HC2P versions: 10 different intensification factors
PIN: 0.4 bar vacuum to 2 bar in suction line (inlet pressure)
PH: 800 bar maximum (outlet pressure)
Intensification ratios: PH = (PIN – PReturn) i (Intensification)
Mounting: Inline tube
Rotation speed: Minimum 1,200 min-1 / maximum 3,000 Min-1
Starting torque: Max. starting torque 0.14 Nm
Power Consumption: 87 W
Accessories: Pilot operated dump valve available
A model = no dump valve
G model = direct proportionally controlled
Description
Description of the HC2P miniBOOSTER hydraulic intensifier
The HC2P is a self priming Booster Pump supplying a pressure up to 800 bar. It is ideal for use in a variety of applications where no hydraulic system is available. The Booster Pump is a combination of a gear pump and the HC2 miniBOOSTER.
Like other miniBOOSTER models, the HC2P automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out on the low-pressure side (gear pump). Relative to its flow capability, the HC2P is a compact unit weighting only 2.1 kg.
Flow Rates
Intensification factor |
Max. outlet flow |
Max. outlet pressure |
---|---|---|
1.2 |
0.12 |
60 |
1.5 |
0.10 |
75 |
2.0 |
0.08 |
100 |
2.8 |
0.06 |
140 |
3.2 |
0.25 |
160 |
4.0 |
0.20 |
200 |
5.0 |
0.16 |
250 |
6.6 |
0.13 |
330 |
9.0 |
0.09 |
450 |
13.0 |
0.06 |
650 |
Dimensions

Functions
The basic operation is illustrated in the function diagram. From the suction inlet oil is drawn into the gear set of the pump, where the pressure is increased to approx. 40 bar and fed to the IN port of the booster, where it flows freely through the check valves RV, KV1 and KV2 to the high pressure side H.
When end pressure is reached on the high pressure side H, valves KV1 and KV2 will close. The end pressure will be achieved by the oscillating pump unit OP. If there is a pressure drop on the high pressure side due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.
When the pump is stopped, there will be no pressure on the IN-port and Pilot Supply 2, causing the RV to open allowing the fluid to return to the tank
Function Diagram

Connection types
Connection |
H / S |
---|---|
1 |
1/4" BSP |
Max. tightening torque BSP
H / S | |
---|---|
1/4" BSP |
|
with steel washer |
4.0 da/Nm |
with aluminium washer |
3.0 da/Nm |
with cutting edge |
4.0 da/Nm |
Fluids and materials
Please see General Specifications
Ordering a HC2P
Ordering example of a HC2P with i = 9.0, DV incorporated and BSP connections: HC2P - 9.0 - G - 1
Model |
Intensification, i |
Dump Valve |
Connections |
|||
HC2P |
your selection... |
your selection... |
your selection... |
|||
see flow rate table |
A = (no) / A model |
1 |
||||
G = (proportional) / G model |